MedPerf evaluates AI models across hospitals without moving patient data. It sends the model to the data. Data are accessed and analysed locally at each participating site, metrics are uploaded only if the site approves them, and no patient data reaches the MedPerf server. MedPerf gives evidence of how a model performs on unseen data from distinct out-of-sample sources. It does not check whether the generator behind your augmentation memorised its training patients, because MedPerf leaves training-data privacy to model owners. Its stated aim is to provide evidence of generalised performance to regulators.

One point to settle first. The MedPerf studies cited here benchmark segmentation and classification models, such as the 41 brain-tumour segmentation models in the FeTS challenge. Applying the platform to a GenAI-augmented model is a transfer, not a documented use, so the sections below say where that transfer holds and where it does not.

How MedPerf runs a model inside a hospital without the images leaving

A MedPerf benchmark is defined by three containers: a Data Preparator, a Reference Model and a Metrics container. The Data Preparator converts each site’s data standards into one unified format, checks quality and compatibility, and computes statistics and metadata for registration. The model container exposes one task, infer, which reads the prepared data and writes predictions. The Metrics container compares those predictions with the ground-truth labels and writes the metrics to a YAML file.

Containers have no network access at runtime, so any download or upload attempt fails. They run as a non-root user, and input volumes are mounted read-only. The MedPerf server holds the metadata needed to coordinate experiments and no code assets or datasets. The client does the dataset preparation and runs experiments on the local machine.

When a run finishes, the data owner reviews the results and decides whether to submit them. The benchmark committee’s sharing policy then sets how much detail is published, anywhere from a single aggregated metric to the full cross product of models and datasets. For a synthetic-augmented model the cross product is the better choice, because the variance between sites is the evidence, and a single pooled number hides it. The wider workflow, apart from the generative question, is covered in our explainer on MedPerf for medical AI generalisability.

Using MedPerf for generative medical imaging models

In MedPerf, the model container runs inference on prepared data and the Metrics container scores its predictions. In a GenAI-augmented pipeline, the model to benchmark is the downstream diagnostic or segmentation model trained on real and synthetic images. That framing decides how to design the study.

The stronger design puts two model containers in the same benchmark: one trained on real data only and one with synthetic augmentation. Both are evaluated on the same sites. In that design, the per-site difference between them is the claim to defend. A single augmented model scoring well tells you less, because you cannot tell whether the synthetic data helped, did nothing, or hid a weakness that the real data would have exposed.

The published results point both ways on the direction of that difference. Ktena et al. (Nature Medicine, 2024) found that synthetic images from diffusion models made models more robust and fairer in histopathology, chest X-ray and dermatology, especially out of distribution. Their improvements were particularly striking when training data was scarce. A 2025 federated benchmark of medical image classification by Zhou et al. found that adding DDPM-generated images helped convergence, but final accuracy fell short of optimal, possibly because the generated data misled the classifiers. In one dataset that was already large, the augmentation hurt performance. A federated benchmark across real sites is how you find out which of these happened to your model.

The test data has to be real patient data. The FDA’s M-SYNTH regulatory science tool, a synthetic mammography dataset, states that it cannot fully replace real patient data for evaluating mammography AI. It also warns that a domain gap between real and synthetic examples risks misjudging model performance. MedPerf runs each evaluation on the data held at each participating facility.

What a multi-site benchmark shows that an internal test set hides

An internal test set shares the hidden regularities of the training data, such as scanner, acquisition protocol, image processing and disease prevalence. A model can score well on that set by learning those regularities instead of the pathology. Zech et al. (PLOS Medicine, 2018) showed this for pneumonia-screening CNNs on chest radiographs. A model trained jointly on two hospital systems reached an internal test AUC of 0.931 but only 0.815 at an external hospital in Indiana. A separate CNN identified the source hospital system for 99.95% of NIH radiographs. Using cohorts engineered to vary pneumonia prevalence, the authors showed that the more strongly a hospital system predicted pneumonia, the more the models used that signal, and the worse they generalised.

Synthetic augmentation should not be assumed to remove this problem. Zhou et al. observed that diffusion-generated images had a more uniform pixel distribution across clients than the real data. That smooths the feature shift during training, but it is no evidence about how the model behaves on a new site’s scanner.

FeTS shows what a multi-site run surfaces in practice. Evaluating 41 models across 32 institutions on six continents, the organisers found that models generalised well at many sites but performance dropped at others. Even the top-ranked model showed instances of failure at institutions whether or not they had contributed training data. The challenge ranked models per institution and weighted each site equally, so that sites with many cases would not dominate the result. For deployment decisions, the worst-performing site matters more than the median, because FeTS found failures at some sites despite good median performance. Near-perfect accuracy is rarely a realistic expectation, so the clinical workflow around the model needs fault tolerance and a human in the loop. If you are building the dataset side of this yourself, our guide to designing a validation set for a medical imaging AI covers how to stratify it.

Can a site-by-site benchmark tell memorisation from generalisation?

Only partly. Strong performance across unseen sites is good evidence that the downstream model is not overfitted to its training institutions. Memorisation is a different property of the generator. It asks whether the generator reproduces real training patients as “synthetic” images, and you measure it on the generator against its own training set, which MedPerf does not touch.

Studies have measured the risk. In a study in Nature Biomedical Engineering (2025), unconditional latent diffusion models memorised about 37.2% of patient data, and 68.7% of their synthetic samples were identified as copies of patient data. The same study found latent diffusion models more susceptible to memorisation than autoencoders and GANs. The authors of the DeepSSIM metric (2025) cite earlier work in which diffusion models leaked 59% of a small angiography training set and 33% of a larger knee MRI set. A comparison on brain MRI and chest X-ray found diffusion models more likely to memorise than StyleGAN, especially on small datasets and on 2D slices taken from 3D volumes.

FID and IS do not account for memorisation, and generative models with better FID scores often memorise more. The sources cited here describe four detection approaches:

  • Pixel-wise correlation between each synthetic image and its closest training image, which is simple and sensitive to fine detail.
  • Embedding nearest-neighbour thresholds: HyFree-S3 discards any synthetic image whose OpenCLIP distance to a real image falls below the 5th percentile of real-to-real distances.
  • Self-supervised copy detection, the approach the Nature Biomedical Engineering study used.
  • Learned similarity metrics such as DeepSSIM, trained so that embedding similarity matches SSIM computed in image space.

Filtering has limits. The HyFree-S3 authors state that no official, internationally accepted guidelines define memorisation of imaging data. They also state that their method cannot give mathematical guarantees that no memorisation occurs. On the mitigation side, training-time augmentation, smaller architectures and larger datasets reduced memorisation, while overtraining increased it. The memorisation audit belongs next to the MedPerf results in the evidence pack as a separate artefact, never implied by the benchmark.

Who does what in a MedPerf study of a GenAI-augmented model

Role Who it usually is What it does in MedPerf What it should add for a synthetic-augmented model
Benchmark committee Challenge organisers, clinical trial organisations, regulators, foundations, healthcare stakeholders Defines the clinical task, patient inclusion criteria, labelling method and metrics; submits the three reference containers; approves models and datasets Subgroup and per-site metrics in the Metrics container, and a sharing policy detailed enough to show variance between sites
Model owner ML researchers and software vendors with a trained model Submits a model container that must pass a local compatibility run before the committee approves it A real-only baseline next to the augmented model, plus the generator’s memorisation audit, which MedPerf does not produce
Data provider Hospitals, practices, research organisations, payors Prepares, labels and reviews data under its own legal and ethical requirements, runs the models locally, approves results Sites and scanners that did not contribute to training either the generator or the classifier
Platform provider Organisations such as MLCommons Operates the platform that committees build benchmarks on Nothing specific to generative models

Multi-site coordination is substantially time-consuming. In FeTS, setting up the evaluation across all sites took several weeks, and communication was the main bottleneck. Several sites reported GPU compatibility issues with converted BraTS submissions, which left some model evaluations missing, although the recommended base Docker image ran at every site. When the organisers screened the reference segmentations they could access, 125 of the 1,201 cases (10.4%) had major annotation errors. Missing metadata at the sites also limited how far failures could be explained. The other side of the trade is that MedPerf builds most technical safeguards into the design, which leaves data-sharing agreements to cover simpler provisions and can speed up legal sign-off.

Federated benchmarking is not federated learning, and validation depends on the difference

Federated learning trains a model. Federated evaluation tests one that is already trained. The two share the idea of keeping data distributed and moving the algorithm, but they move different things with different risks.

  Federated learning Federated evaluation (MedPerf)
What travels to sites A model to be trained locally, round after round A finished, trained model
What comes back Model weight updates, aggregated into a new global model Evaluation metrics, only if the site approves them
Network during the workload Needed for repeated exchanges with the aggregator Not needed; containers run with no network access
Information exposed Weight updates, which carry far more information than metrics Metrics, generally orders of magnitude less information
Distinct risk Potential data leakage through shared gradients Submitting the model to evaluation sites, which raises model privacy concerns
Output A trained model Evidence of performance on unseen data

This matters for validation for a structural reason. Consider a federated-trained model, such as one augmented with locally generated DDPM images as in Zhou et al., tested only on its training sites. By Zech et al.’s definition, that is internal performance, not external performance. Independent federated evaluation on sites outside the training federation is what turns a federated training result into generalisation evidence.

Where MedPerf evidence ends and regulatory clearance begins

MedPerf addresses a need regulators share. Regulatory agencies agree on the need for large-scale validation to measure generalisability quantitatively, and MedPerf’s stated aim is to provide evidence of generalised model performance to regulators, providers and patients. It also keeps records of which steps were run, by whom and with what results, to make experiments traceable. That evidence goes into a submission.

The submission is defined elsewhere. The FDA’s January 2025 draft guidance on AI-enabled device software functions sets out what marketing submissions should contain to support the agency’s evaluation of safety and effectiveness across the total product life cycle. The evaluation of safety and effectiveness is the FDA’s. Our page on where engineering validation stops under FDA device regulation covers that handover in detail.

Clearance does not settle trustworthiness either. An audit of 519 FDA summary reports for AI/ML-enabled devices found that 24.7% gave no evidence for any FUTURE-AI trustworthiness principle and that none covered all six. Traceability was documented in 8.3% of reports and explainability in 3.5%. The authors concluded that regulatory approval alone should not be considered a proxy for trustworthiness. They called for pre-deployment assessments across populations, devices and care settings, plus post-deployment monitoring for drift. A multi-site MedPerf benchmark covers part of the first. Post-deployment drift monitoring is outside MedPerf’s stated objectives.

Our account of a clinical-grade imaging validation engagement covers the wider work around the benchmark.

The gap that remains

MedPerf’s developers say future versions will add features for model privacy and possibly a secure container registry. They also acknowledge that model privacy helps defend against model inversion attacks, in which a model is used to reconstruct its training data. Until then, and with no accepted definition of memorisation for imaging data, a synthetic-augmented model needs two separate evidence lines. MedPerf evaluates the model on unseen data from distinct sources. A memorisation audit of the generator checks whether the synthetic images copy patient data. A submission that merges these two lines into one claim leaves the memorisation question unanswered.